Device Specifications
Flow Range: 0 to 300 SLM (Standard Liters per Minute)
Analog Voltage Output (3):
Minimum: 1 VDC;Maximum: 5 VDC
Zero Point Voltage:
Minimum: 0.95 VDC;Maximum: 1.05 VDC
Zero Drift: Up to 0.2% of Full Scale (%F.S)
Resolution (4): 0.1% of Full Scale (%F.S)
Load: Up to 100 KΩ
Definition:
Minimum: 2% F.S.,Maximum: 3% F.S.
Response Time:
Minimum: 1 msec,Maximum: 3 msec
Supply Voltage (5):
Minimum: 8 VDC,Nominal: 12 VDC,Maximum: 24 VDC
Supply Current:
Minimum: 20 mA,Maximum: 30 mA
Overall Material: Silicon carbide, epoxy, PS (possibly
Polystyrene), FR 4 (a type of fiberglass-reinforced epoxy
laminate), silicon as seal
Customization: Indicates differentiation in materials used.
Interpretation and Notes
Flow Range: The device measures flow rates from 0 to 300 Standard
Liters per Minute (SLM).
Analog Output: Provides a voltage output ranging from 1 to 5 VDC
corresponding to the flow rate.
Zero Point Stability: The zero point voltage remains stable within
0.95 to 1.05 VDC, with a maximum drift of 0.2% F.S.
Resolution: Specifies the smallest increment of flow that can be
detected, set at 0.1% of Full Scale.
Load and Definition: Defines the electrical load capacity and the
accuracy tolerance (2% to 3% of Full Scale).
Response Time: Indicates how quickly the device responds to changes
in flow rate, ranging from 1 to 3 milliseconds.
Power Requirements: Operates on a supply voltage ranging from 8 to
24 VDC, with a current draw between 20 to 30 mA.
Material Composition: Lists materials used in construction,
highlighting silicon carbide and various types of epoxy and
laminate.
![]() |