Sign In | Join Free | My himfr.com
Home > Flowmeter >

CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable

Wuxi Consensic Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable from wholesalers
     
    Buy cheap CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable from wholesalers
    • Buy cheap CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable from wholesalers

    CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable

    Ask Lasest Price
    Brand Name : Consensic
    Model Number : CAFS5012E
    Certification : PTC23041812701C-CN01
    Price : Offline conversation or face-to-face discussion
    Payment Terms : L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
    Supply Ability : 999
    Delivery Time : 3-7 work days
    • Product Details
    • Company Profile

    CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable


    Key Features of the CAFS 5012E Series Explosion-Proof Gas Mass Flowmeter

    • Intrinsically Safe and Explosion-Proof: Certified as Ex ia IIC T6 Ga, ensuring safety in hazardous environments.
    • High Accuracy: Achieves 1.5% Full Scale (F.S.) precision with high long-term zero-drift stability.
    • Fast Response Time: Features a fast response time of 10 ms (customizable up to 150 ms, with factory default set at 65 ms).
    • Wide Flow Range: Can measure flow rates from 0-60 m/s, 100g.
    • Robust and Reliable: Solid-state sensing core without surface cavities or fragile films, resistant to blockage and pressure impacts.
    • Humidity Adaptation: Suitable for relatively humid gas measurements and resistant to condensate.
    • Multiple Output Options: Provides analog output (1-5 V), I2C, or RS485 digital communication options.
    • Temperature and Humidity Tolerances:Operating Temperature: -15°C to 65°C;Storage Temperature: -25°C to 85°C;Humidity: 0-100% RH

    Functional Items and Performance Parameters

    • Flow Range: Customizable from 0-50, 80, 100, 150, 200, 250, 300, 400 SLPM
    • Power Supply Voltage: 8~24VDC, 50mA
    • Explosion-Proof Type: Ex ia IIC T6 Ga
    • Accuracy: ±1.5% F.S.
    • Response Time: Customizable to 10, 20, 65, or 150 ms (factory default 65 ms)
    • Maximum Pressure: Customizable up to 0.8 MPa
    • Output Method: Analog output 1-5 V, digital RS485, or I2C (optional)
    • Temperature Range:Medium Temperature: -10~65°C;Ambient Temperature: -25~85°C
    • Connection Type: G1/2 (customizable)
    • Calibration Method: Calibrated with air at 20°C, 101.325kPa
    • Material: Aluminum alloy (customizable to stainless steel)

    Communication

    1. I2C Communication: For detailed communication protocol, please contact the manufacturer.
    2. RS485 Communication:The flowmeter uses RS485 communication with two protocol modes (factory default is B mode):B. Modbus Agreement: Multi-machine communication protocol.;A. Factory Calibration Communication Protocol: Stand-alone communication protocol.Settings:Parity/Flow Control: None;Stop Bit: 1;Data Bit: 8;Baud Rate: 9,600;Communication Protocol: Refer to the CAFS 5000 series gas mass flowmeter upper computer Modbus communication protocol for detailed instructions.

    Product Models and Specifications

    Product ModelLatus Rectum (mm)JoggleL (mm)H (mm)W (mm)d (mm)Specifications
    CAFS 5012E19G1/213066451950/80/100/150/200/250/300/400 SLPM

    Differentiation and Features:

    1. Intrinsic Safety and Explosion-Proof:Certified for use in hazardous environments, ensuring safety and compliance with Ex ia IIC T6 Ga standards.
    2. High Precision and Stability:Delivers high accuracy (1.5% F.S.) and long-term zero-drift stability, essential for precise gas measurement applications.
    3. Fast and Customizable Response Time:Offers a quick response time of 10 ms, customizable to meet specific application needs (factory default is 65 ms).
    4. Versatile Measurement Range:Can handle a wide flow range from 0-60 m/s, 100g, making it suitable for various industrial applications.
    5. Durable and Reliable Design:Features a solid-state sensing core, resistant to blockage and pressure impact, with no surface cavities or fragile films.Suitable for humid gas environments and resistant to condensate.
    6. Flexible Output and Communication Options:Provides multiple output methods including analog (1-5 V), digital RS485, and I2C for flexible integration with different systems.Offers detailed communication protocols for both factory calibration and Modbus agreements.
    7. Robust Construction:Constructed from aluminum alloy with optional customization to stainless steel, ensuring durability and longevity in demanding environments.
    8. Environmental Resilience:Operates effectively in a wide temperature range (-15°C to 65°C) and can be stored at temperatures ranging from -25°C to 85°C.Capable of withstanding 0-100% relative humidity, ensuring reliable performance in various conditions.
    Quality CAFS5012E Response Time 10,20,65,150 (Factory Default 65) Ms Customizable for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuxi Consensic Electronic Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)