Sign In | Join Free | My himfr.com
Home > Medical Flow Sensors >

Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors

Wuxi Consensic Electronic Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors from wholesalers
     
    Buy cheap Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors from wholesalers
    • Buy cheap Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors from wholesalers

    Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors

    Ask Lasest Price
    Brand Name : Consensic
    Model Number : CAFS5012E
    Price : Offline conversation or face-to-face discussion
    Payment Terms : L/C/Ade/Pellet/Texi Union, MoneyGram, Alipay, and business-to-business payments
    Delivery Time : 3-7 work days
    Certification : PTC22072602101C-CN01
    Supply Ability : 999
    • Product Details
    • Company Profile

    Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors

    Product Presentation

    CAFS5012E Explosion-proof gas mass flowmeter is using microelectromechanical system (MEMS) flow sensor chip, suitable for various uses of clean, relatively dry gas flow measurement and process control, unique packaging technology to satisfy the different range of flow measurement, to ensure high sensitivity, high reliability, high stability and low cost.

    CAFS5012E Is based on MEMS flow sensing unit and high precision digital processing and calibration circuit (MCU). The integrated Δ - Σ A / D converter, the logic circuit with internal calibration function and MCU processor jointly guarantee the real-time effective acquisition of sensing signal, obtain accurate flow signal, and the corresponding compensation algorithm processing, without any external calibration compensation to ensure the high precision flow output; in addition, the product adds the power system, connection, port system and other protection circuits; friendly digital output communication mode, users can easily get the communication and get the corresponding data information; the product application range is very broad.


    Performance Parameters Products



    Functional items

    Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors

    Performance parametersunitremark
    Flow range0-50,80,100,150,200,250,300,400SLPMCustomizable
    Power supply8~24VDC,50mAVDC
    Explosion-proof typeEx ia IIC T6 Ga
    precision±1.5%F.S.
    Response time10 ,20 ,65 ,150 (factory default 65)msCustomizable
    Maximum pressure0.8MPaCustomizable
    Output modeAnalog output 1-5, digital RS485 or I2C (optional)VDC
    temperatureMedium temperature(-10~65)
    Ambient temperature (-25~85)
    interfaceG1/2Customizable
    Calibration methodAir, 20°C, 101.325kPa
    Overall materialAluminum alloy (stainless steel can be customized)

    Precautions.


    1. Please read the manual carefully before using the product.
    2. The product is best used in a clean gas environment; It is not suitable for environments with a large amount of dust, oil and multiphase flow; For there are a large number of them.
    3. For use in a vapor environment, please contact the manufacturer in advance.
    4. The product is suitable for gas measurement, monitoring and control in various gas, industrial, medical, commercial, instrumentation and other industries. Others don't the use in a suitable environment should be strictly controlled.
    5. When using or applying this product, the corresponding relevant operating specifications and safety precautions and procedures for operators should be strictly followed.
    6. Wuxi Consensic Electronic Technology Co., Ltd. and its branches, subsidiaries, offices and other affiliates will not be responsible for any impropriety.
    7. Responsibility for damages arising from the use of this product. All other matters are subject to the sales contract. Please read the instructions carefully before using the product.

    Matters Needing Attention


    1.The product can only work normally in the use environment defined in this manual.

    2.Attention should be paid to the gas flow mark during installation, and the connection and leakage detection should be carried out according to the corresponding regulations.

    3.During the use of the product, the online installation of pipes, cleaning of pipes or other operations that may introduce a large amount of impurities may cause damage to the product.If there is water in the medium, or immersed in water may cause the decline or damage of the sensor sensitive characteristics.

    4.The positive and negative electrode of the power supply will cause the internal circuit of the sensor burned out, thus affecting the use.

    Quality Flow Range 0-50 80 100 150 200 250 300 400SLPM Medical Flow Sensors for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuxi Consensic Electronic Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)